The M10 is the medium capacity meter in the M-SERIES™ range. It has the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability.

Features

  • Compact size.
  • Two independent pulse units which can be linked to allow doubling of the pulse output.
  • Flexibility of installation options (e.g. can be mounted horizontally or vertically; no flow conditioning required).
  • Low pressure drop allows for economical pump selection or gravity flow applications.
  • Meter construction enables fast and easy on-site servicing without removal from application.
  • Meter design minimises the number of wearable and replaceable parts and extends product life.
  • Meter accuracy is verified by a factory calibration check after which an individual metrology report is issued.
  • LC Display meets European CE directive for EMC.
  • Deluxe/Standard Displays Pulse Version have IP65/NEMA9 protection.
  • Intrinsically safe LC Deluxe & Standard Displays. Certificate of conformity numbers PTB Nr. Ex-93.C.4033x & KEMA O5ATEX1168X
  • Pulse versions have Flameproof Certification AUS Ex2377x

Specification:

Model M10/WM10
Meter Type Pulse / Standard LC Display / Deluxe LC Display / MR100 LC Display
Meter Type Pulse / LCD
Meter Body Material Aluminium / 316 Stainless Steel / Bronze
Wetted Components:
Rotor Material
Shafts
O'ring
PPS / 316 Stainless Steel
316 Stainless Steel
NBR (Nitrile)
Flow Rate Ranges
(Litres Per Minute/US Gallons Per Minute)
Above 5 cPs
Below 5 cPs
6 To 120 / 1.6 To 32
10 To 100 / 2.6 To 26
Accuracy- Within (Of Reading) +/- 0.5%
Repeatability 0.03%
Maximum Viscosity (Of Standard Model) 1000 Centipoise (optional hi viscosity rotors)
Maximum Operating Pressure 5500kpa/ 800 Psi/ 55 Bar Flange Rule Where Fitted
Pulser Type Hall Effect or
Reed Switch or
Combination HE / RS
Pulses Per Litre/Us Gallon 36 /136.3 With Dual Pulse Output 72 / 272.6
Max. Operating Temperature 80°C / 176°F, High Temp Option 120°C / 248°F
Recommended Mesh Strainer Size 60 Mesh

 


Port Size

To order flowmeter you must replace ‘X’ with the relevant number. This number will determine the following specifications:

Port Size: Calibrated and
Display In:
Electrical
Conduit Connection:
1 = 1” BSP (F) ports Litres 20mm (F)
2 = 1” NPT (F) ports US Gallons ½” NPT (F)
3 = 1” ANSI 150lb Flange Litres 20mm (F)
4 = 1” ANSI 150lb Flange US Gallons ½” NPT (F)
5 = 25mm DIN 16 Flange Litres 20mm (F)
6 = 1” Triclover Flange Litres 20mm (F)
7 = 1” Triclover Flange US Gallons ½” NPT (F)
13=25mm JIS 10K Flange Litres 20mm (F)

PPS = Polyphenylene Sulfide Resins
Bronze = Available in 1 or 2 port configuration only


Special Models:

M10ARPH-X High Pressure Version
M10SSPH-X High Pressure Version
Threaded Versions Only Working Pressure 13800 kPa / 2000 PSI / 138 BAR

Available Options: All as listed


Options and accessories

WM10 - 1” PULSE AND LC DISPLAY METERS
M10 - 1” PULSE AND LC DISPLAY METERS
WM10ARX-X
M10ARX-X
WM10ASX-X
M10ASX-X
WM10SRX-X
M10SRX-X
WM10SSX-X
M10SSX-X
WM10BRX-X
M10BRX-X
FKM O-Ring Ο Ο Ο Ο Ο
FEP O-Ring Ο Ο Ο Ο Ο
EPDM O-Ring Ο Ο Ο Ο Ο
High Temp Rotors Ο Ο Ο
High Viscosity Rotors Ο Ο Ο Ο Ο
Hall Effect Sensor Ο Ο Ο Ο Ο
Reed Switch
Solvent Kit - - - - -
Hastalloy C Shafts - - - - -
Protective Boot Deluxe LCD + + + + +
Protective Boot Standard Display + + + + +
Remote Mounted LC Display + + + + +
Heating Jacket + + + + +
4-20mA Module + + + + +

• Standard   Ο Optional   - Not Available   + Accessory