M4 - 1/2" pulse and LC display meters

The M4 is a low to medium flow range model. It is a compact meter that has the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability.

Features

  • Compact size.
  • Two independent pulse units.
  • Flexibility of installation options (e.g. can be mounted horizontally or vertically; no flow conditioning required).
  • Low pressure drop allows for economical pump selection or gravity flow applications.
  • Meter construction enables fast and easy on-site servicing without removal from application.
  • Meter design minimises the number of wearable and replaceable parts and extends product life.
  • Meter accuracy is verified by a factory calibration check after which an individual metrology report is issued.
  • All LC Displays meet European CE directive for EMC.
  • Display/Pulse Version has IP65/NEMA9 protection.
  • Intrinsically safe LC Deluxe & Standard Displays. Certificate of conformity number PTB Nr. Ex-93.C.4033x & KEMA O5ATEX1168X 

 


 

Specification:

Model M4
Meter Type Pulse / Standard LC Display / Deluxe LC Display/MR100 Display
Meter Body Material Aluminium / 316 Stainless Steel / Bronze
Wetted Components:
Rotor Material
Shafts
O'ring
PPS / 316 Stainless Steel
316 Stainless Steel
NBR (Nitrile)
Flow Rate Ranges
(Litres Per Minute/US Gallons Per Minute)
Above 5 cPs
Below 5 cPs
2 To 30 / 0.5 To 8
3 To 25 / 0.8 To 6.60
Accuracy- Within (Of Reading) +/- 0.5%
Repeatability 0.03%
Maximum Viscosity (Of Standard Model) 1000 Centipoise (Optional Hi Viscosity Rotors)
Maximum Operating Pressure 5500kpa/ 800 Psi/ 55 Bar
Pulser Type Hall Effect or
Reed Switch or
Combination HE / RS
Pulses Per Litre/Us Gallon 112/424
Max. Operating Temperature 80°C / 176°F, High Temp Option120°C / 248°F
Recommended Mesh Strainer Size 60 Mesh

*Note: For doubled pulse output or SAA flame proof certification use M5 series models (contact for more info)

 


 

Port Size:

To order flowmeter you must replace ‘X’ with the relevant number. This number will determine the following specifications:

Port Size: Calibrated In: Electrical Connections
1 = ½” BSP (F) ports Litres 20mm (F) Conduit Thread
2 = ½” NPT (F) ports US Gallons ½” NPT

PPS = Polyphenylene Sulfide Resins

 

Special Models

M4SSPH-X High Pressure Version
Threaded Versions Only 200 Bar / 2900 PSI Working Pressure

Available Options: Pulse LC Displays - Hi Viscosity Rotors

 


 

Options and accessories

M4 - ½” PULSE AND LC DISPLAY METERS M4ARX-X M4ASX-X M4SRX-X M4SSX-X M4BRX-X
FKM O-Ring Ο Ο Ο Ο Ο
FEP O-Ring Ο Ο Ο Ο Ο
EPDM O-Ring Ο Ο Ο Ο Ο
High Temp Rotors Ο Ο Ο
High Viscosity Rotors Ο Ο Ο Ο Ο
Hall Effect Sensor Ο Ο Ο Ο Ο
Reed Switch
Solvent Kit - - - - -
Hastalloy C Shafts - - - - -
Protective Boot Deluxe LCD - + + + Ο
Protective Boot Standard Display LCD - + + + Ο
Remote Mounted LC Display + + + + +
Heating Jacket - - - - -
4-20mA Module (Meter or Remote Mount) + + + + +

• Standard   Ο Optional   – Not Available   + Accessory